OPTIONS:
Pre-alarm option
• Provides a pre-alarm set point
• (2) additional mechanical NO/NC relay outputs (8A);
External alarm Package
• Multi tone programmable electronic alarm (LVMT4-115-SBOX) (110 VAC)
000810-32 laser extension cable M12 M to F
• Male to Female
• 32 ft long
• 5 pin sealed threaded sealed connector
Override options:
LVX0072PKG 30mm inductive prox sensor, 5m cable, bracket
• Use as hoist side pull override detecting wire rope in lands of drum
• Purchaser responsible for making frame to mount
• Use as hoist side pull override detecting wire rope in lands of drum
• Purchaser responsible for making frame to mount
• 24 VDC; wire to controller; do not need override relay option
The Crane Sentry® Wire Rope Hoist Side Pull Detection is capable of detecting excessive side pull on a wire rope hoist and alerting the operator of the condition or disabling functions.
Reasons For Side Pull Detection
1. Damage to Hoist
Most standard hoists are not engineered to handle side pull load
2. Personnel Injury
Injury is possible if the load shifts once it is lifted from its resting place on the floor or a staging fixture
3. Damage to Equipment
Damage to nearby equipment is possible once the load shifts after it is lifted
Why Crane Sentry® Wire Rope Hoist Side Pull Detection?
- Usage of hoists for lifting loads in industrial applications has inherent risk, requiring the need for safety precautions
- If a load is not lifted directly vertical and is permitted to side load a hoist, referred to as “side pulling”
- Side pulling can damage to the hoist, injury to personnel, and/or damage to nearby equipment
- Detection of potential side pull conditions can be tied into hoist controls to not permit a lift under this condition
- Side pulling a hoist is not permitted by OSHA regulations under most conditions
- Many hoists installed in industry do not have any form of side pull protection installed
Our Solution
- Solid state side pull detection system consists of an
assembly that mounts to the wire rope - Mount assembly to the dead end (fixed end) or
around the equalizer sheave - Install on single or double reeved hoists
- Adapts to a range of wire rope diameters
- Controls mount to the hoist or trolley and provide an
intuitive menu driven interface - One button zero feature
- Set limits, timing, hysteresis
- Built in error logging (time and date); last 5 event
CONTROL SPECIFICATIONS | ||
Power Requirement | 0.5 A @ 110 VAC | |
Number of Outputs | 2 | |
Relay Output Type | SPST NO/NC; rated for 100k operations at max load | |
Rated Current | 8A max per output | |
Rated Voltage | 250 VAC | |
Graphic Display Type | STN LCD, Backlight Illumination, 2 line display | |
Operating Temp (Control Box) | 0ºC to 50ºC | |
Storage Temp | -20ºC to 60ºC | |
Memory Backup | 7 years typical at 25ºC | |
Ingress Protection | IP65 | |
Enclosure Material | Polycarbonate | |
SENSOR SPECIFICATIONS | ||
Max Measuring Range | +/- 90º per axis | |
Measuring Axis | Output = Omnidirectional (combination of X and Y) | |
Operating Temp | -40ºC to 85ºC | |
Ingress Protection | IP67 | |
Sensor Assembly | Fits wire ropes sizes 5-20mm |
Includes
Controller P/N 001017-03
- Connects to (1) 2 axis sensor
- M12 quick connect cable
- Simple and intuitive menu driven controls show set point and live readings
- Set limits
- Manual zero feature;
- Set hysteresis, error time out, and delay
- Built in error logging (time and date); last 5 events
- 2) Mechanical NO/NC relay outputs (8A); behavior is user configurable
- X/Y omnidirectional axis limit (upper/lower)
- X/Y omnidirectional axis auxiliary limit (upper/lower)
- 110 VAC/220 VAC single phase power required; control box self-powers the connected sensors
- Polycarbonate wall mount sealed enclosure mounts on hoist
Sensor head assembly, Low profile P/N 001371
- Solid state sensor
- (2) axis with +/-90 deg range each axis
- M12 quick connect cable
- IP67 ingress protection ; fully potted and sealed (internal sensor head only)
- 12-30 VDC self-powered from controller
- -40 .. +80°C operating temp
- Frequency response: 10 Hz.
- Sensor accuracy: +/-0.4 deg at best; with 0.1 deg resolution Accuracy may be dependent upon mounting orientation.
- Accepts wire rope clamp assembly
- Aluminum and stainless steel construction
Wire rope clamp bracket assembly;
- Specify wire rope dia range at order
- 5-12 mm dia / 12-20 mm dia
- Clamps near dead end of wire rope, on side of equalizer sheave, or near equalizer bar
LV77 3430 0000 50005 0500 quick connect cable;
- M12 sealed connector for sensor; 15 ft 5 pin M-F
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
OPTIONS:
Pre-alarm option
• Provides a pre-alarm set point
• (2) additional mechanical NO/NC relay outputs (8A);
External alarm Package
• Multi tone programmable electronic alarm (LVMT4-115-SBOX) (110 VAC)
000810-32 laser extension cable M12 M to F
• Male to Female
• 32 ft long
• 5 pin sealed threaded sealed connector
Override options:
LVX0072PKG 30mm inductive prox sensor, 5m cable, bracket
• Use as hoist side pull override detecting wire rope in lands of drum
• Purchaser responsible for making frame to mount
• Use as hoist side pull override detecting wire rope in lands of drum
• Purchaser responsible for making frame to mount
• 24 VDC; wire to controller; do not need override relay option
The Crane Sentry® Wire Rope Hoist Side Pull Detection is capable of detecting excessive side pull on a wire rope hoist and alerting the operator of the condition or disabling functions.
Reasons For Side Pull Detection
1. Damage to Hoist
Most standard hoists are not engineered to handle side pull load
2. Personnel Injury
Injury is possible if the load shifts once it is lifted from its resting place on the floor or a staging fixture
3. Damage to Equipment
Damage to nearby equipment is possible once the load shifts after it is lifted
Why Crane Sentry® Wire Rope Hoist Side Pull Detection?
- Usage of hoists for lifting loads in industrial applications has inherent risk, requiring the need for safety precautions
- If a load is not lifted directly vertical and is permitted to side load a hoist, referred to as “side pulling”
- Side pulling can damage to the hoist, injury to personnel, and/or damage to nearby equipment
- Detection of potential side pull conditions can be tied into hoist controls to not permit a lift under this condition
- Side pulling a hoist is not permitted by OSHA regulations under most conditions
- Many hoists installed in industry do not have any form of side pull protection installed
Our Solution
- Solid state side pull detection system consists of an
assembly that mounts to the wire rope - Mount assembly to the dead end (fixed end) or
around the equalizer sheave - Install on single or double reeved hoists
- Adapts to a range of wire rope diameters
- Controls mount to the hoist or trolley and provide an
intuitive menu driven interface - One button zero feature
- Set limits, timing, hysteresis
- Built in error logging (time and date); last 5 event
CONTROL SPECIFICATIONS | ||
Power Requirement | 0.5 A @ 110 VAC | |
Number of Outputs | 2 | |
Relay Output Type | SPST NO/NC; rated for 100k operations at max load | |
Rated Current | 8A max per output | |
Rated Voltage | 250 VAC | |
Graphic Display Type | STN LCD, Backlight Illumination, 2 line display | |
Operating Temp (Control Box) | 0ºC to 50ºC | |
Storage Temp | -20ºC to 60ºC | |
Memory Backup | 7 years typical at 25ºC | |
Ingress Protection | IP65 | |
Enclosure Material | Polycarbonate | |
SENSOR SPECIFICATIONS | ||
Max Measuring Range | +/- 90º per axis | |
Measuring Axis | Output = Omnidirectional (combination of X and Y) | |
Operating Temp | -40ºC to 85ºC | |
Ingress Protection | IP67 | |
Sensor Assembly | Fits wire ropes sizes 5-20mm |
Includes
Controller P/N 001017-03
- Connects to (1) 2 axis sensor
- M12 quick connect cable
- Simple and intuitive menu driven controls show set point and live readings
- Set limits
- Manual zero feature;
- Set hysteresis, error time out, and delay
- Built in error logging (time and date); last 5 events
- 2) Mechanical NO/NC relay outputs (8A); behavior is user configurable
- X/Y omnidirectional axis limit (upper/lower)
- X/Y omnidirectional axis auxiliary limit (upper/lower)
- 110 VAC/220 VAC single phase power required; control box self-powers the connected sensors
- Polycarbonate wall mount sealed enclosure mounts on hoist
Sensor head assembly, Low profile P/N 001371
- Solid state sensor
- (2) axis with +/-90 deg range each axis
- M12 quick connect cable
- IP67 ingress protection ; fully potted and sealed (internal sensor head only)
- 12-30 VDC self-powered from controller
- -40 .. +80°C operating temp
- Frequency response: 10 Hz.
- Sensor accuracy: +/-0.4 deg at best; with 0.1 deg resolution Accuracy may be dependent upon mounting orientation.
- Accepts wire rope clamp assembly
- Aluminum and stainless steel construction
Wire rope clamp bracket assembly;
- Specify wire rope dia range at order
- 5-12 mm dia / 12-20 mm dia
- Clamps near dead end of wire rope, on side of equalizer sheave, or near equalizer bar
LV77 3430 0000 50005 0500 quick connect cable;
- M12 sealed connector for sensor; 15 ft 5 pin M-F
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.