Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

FREE Shipping For Purchases Over $250 within Australia

Fluke Hydra 2638A Data Acquisition System; 20 Channel

SKU: 4410317

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

Need more info? Call us +61 8 9335 1718

The Fluke Hydra Series III continues the Hydra Series legacy of precision, multi-channel data acquisition.

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 4384958, 4410321)

The new Series III improves on Hydra's industry-leading thermocouple accuracy and adds a new dimension to how you collect and view data in a portable system.

DC measurement accuracy of 0.0024%, basic 0.5°C thermocouple accuracy, full-color display, easy-to-use menu system and industrial safety ratings put the 2638A in a category of its own as a precision data acquisition system. The dedicated 6.5 digit digital multimeter (DMM) mode provides additional utility and value.

The 2638A is expandable from 22 to 66 channels of differential analog inputs. A flexible, 22-channel Universal Input Connector lets you connect and disconnect any type of input to any channel, quickly and easily. Selectable inputs include dc voltage, ac voltage, resistance, thermocouple, RTD, thermistor, frequency and dc and ac current. You can also use the 2638A with optional software and other Fluke data loggers to create a flexible, customized data acquisition system with an almost unlimited number of channels.

Other data loggers require you to wire your inputs directly to an expensive “plug-in” active component signal conditioning module. If you need your instrument for a test at another location, you must remove your wiring or use another expensive plug-in signal conditioning module. With Hydra Series III, all your signal conditioning is inside the mainframe, not in your input connector.

Features

  • The 2638A incorporates the Fluke patented Universal Input Connector to bring more accuracy to thermocouple measurements than most other instruments in its class. 
  • The Universal Input Connector plugs into any open slot in the 2638A that contains a relay card.
  • Expandable channel capacity with 3 slots in the rear panel. Each slot can hold a user-accessible relay card and a 22-channel Universal Input Connector. 
  • Graphical color display with easy-to-use menus
  • Displayed text in the menus and data display area are translated to eight languages
  • Real-time data charting with historical review
  • Chart the real-time data of up to four channels at once. Simply select your channels and view real time charting of your measurements.
  • Screen capture function with one key push on the front panel. Capture the screen contents of the 2638A directly to the USB drive in .jpg file format.
  • Each channel can be set for two alarm points: High-High, High-Low or Low-Low, in any combination.
  • Each channel measurement can be set to scale and record your measurement using mx+b gain and offset calculations that are available during your channel setup menu.
  • DMM mode adds functionality and value
  • The Hydra Series III features 20 MB on-board memory for storing over 57,000 data records and configuration files.
  • The main panel memory key opens a simple menu for managing data files and setup files.
  • A totalizer input located on the rear panel provides a simple counter that records to the data file on every scan.
  • Each channel’s measurement statistics can be viewed at any time.
  • USB (virtual serial port) and LAN interface connections are available for easy connection to your company network or direct to you PC.
  • Category II safety rating to help protect you and your operators when making real-world measurements in industrial areas.
  • TQSoft and TQAero thermal validation software
  • Trend Link Software extends system capabilities
  • On-screen color trend graphing of up to four channels at a time
  • Easy-to-use menu system for setup and data management
  • Input types: ac V, dc V, ac I, dc I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency
  • 45 channels/second basic dc scan rate
  • Internal 57,000 scan/setup file memory

Specifications

  • Power:
    • Voltage: 100V to 264A in 4 power model selections (100V, 120V, 220V, 240V)
    • Frequency: 47Hz to 440Hz (automatically sensed when turned on)
    • Power Consumption: 34V A peak (24W average)
  • Universal Channels: 20
  • Channel Capacity:
    • Analog Inputs: 22 to 66 channels; 8  Digital I/O & 6 Alarm
    • Totalizer: 1
  • Temperature:
    • Operating: 0°C to 50°C
    • Storage: 20°C to 70°C
    • Warm-up: One hour to full uncertainty
  • Relative Humidity (non-condensing):
    • Operating: 0°C to 28°C <90%; 28°C to40 °C <75%; 40°C to 50°C <50%
    • Storage: 20°C to 70°C <95%
  • Communication:
    • LAN: 10/100 Mb TCPIP DHCP
    • Remote Commands: SCPI command set
  • DC Volts:
    • Range: 100MV to 300V
    • Resolution:  0.1µV to 1mV 
    • Accuracy: 0.0024%
  • AC Volts:
    • Range: 100 MV to 300 V
    • Resolution: 0.1µV to 1mV
    • Accuracy: 0.11%
  • Resistance:
    • Range: 100 Ω to 100 MΩ
    • Resolution:  0.1 mΩ to 100 Ω
    • Accuracy: 0.01%
  • Frequency:
    • Range: 20 Hz to 1 MHz
    • Accuracy: 0.01%
  • RTD (Pt 100):
    • Range: -200°C
    • Resolution: 0.001°C
    • Accuracy: 0.016°C
  • J Thermocouples:
    • Range: -200°C to 1,000°C
    • Resolution: 0.01°C
    • Accuracy: 0.53°C
  • K Thermocouples:
    • Range: -200°C to 1,000°C
    • Resolution: 0.01°C
    • Accuracy: 0.60°C
  • T Thermocouples:
    • Range: -270°C to 400°C
    • Resolution: 0.01°C
    • Accuracy: 0.62°C
  • Other Thermocouple Types: R, S, N, E, B, C, D, G, L, M, U & W
  • Internal Memory: 57,000 scans; 1000 setup files
  • File Security: Dual level, Administrator, five secure users, Guest status
  • Alarm Outputs: 6 TTL alarm outputs - assignable to one or multiple channels
  • Alarm Setpoints: 2 assignable setpoints/channel, Hi Lo, Hi Hi, Lo Lo
  • Language Menus: English, Chinese, French, German, Japanese, Korean, Portuguese, Russian & Spanish
  • Standard Rack Height: 3 U
  • Dimensions (L x W x H): 385mm x 285mm x 150mm
  • Weight: 6kg
Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

The Fluke Hydra Series III continues the Hydra Series legacy of precision, multi-channel data acquisition.

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 4384958, 4410321)

The new Series III improves on Hydra's industry-leading thermocouple accuracy and adds a new dimension to how you collect and view data in a portable system.

DC measurement accuracy of 0.0024%, basic 0.5°C thermocouple accuracy, full-color display, easy-to-use menu system and industrial safety ratings put the 2638A in a category of its own as a precision data acquisition system. The dedicated 6.5 digit digital multimeter (DMM) mode provides additional utility and value.

The 2638A is expandable from 22 to 66 channels of differential analog inputs. A flexible, 22-channel Universal Input Connector lets you connect and disconnect any type of input to any channel, quickly and easily. Selectable inputs include dc voltage, ac voltage, resistance, thermocouple, RTD, thermistor, frequency and dc and ac current. You can also use the 2638A with optional software and other Fluke data loggers to create a flexible, customized data acquisition system with an almost unlimited number of channels.

Other data loggers require you to wire your inputs directly to an expensive “plug-in” active component signal conditioning module. If you need your instrument for a test at another location, you must remove your wiring or use another expensive plug-in signal conditioning module. With Hydra Series III, all your signal conditioning is inside the mainframe, not in your input connector.

Features

  • The 2638A incorporates the Fluke patented Universal Input Connector to bring more accuracy to thermocouple measurements than most other instruments in its class. 
  • The Universal Input Connector plugs into any open slot in the 2638A that contains a relay card.
  • Expandable channel capacity with 3 slots in the rear panel. Each slot can hold a user-accessible relay card and a 22-channel Universal Input Connector. 
  • Graphical color display with easy-to-use menus
  • Displayed text in the menus and data display area are translated to eight languages
  • Real-time data charting with historical review
  • Chart the real-time data of up to four channels at once. Simply select your channels and view real time charting of your measurements.
  • Screen capture function with one key push on the front panel. Capture the screen contents of the 2638A directly to the USB drive in .jpg file format.
  • Each channel can be set for two alarm points: High-High, High-Low or Low-Low, in any combination.
  • Each channel measurement can be set to scale and record your measurement using mx+b gain and offset calculations that are available during your channel setup menu.
  • DMM mode adds functionality and value
  • The Hydra Series III features 20 MB on-board memory for storing over 57,000 data records and configuration files.
  • The main panel memory key opens a simple menu for managing data files and setup files.
  • A totalizer input located on the rear panel provides a simple counter that records to the data file on every scan.
  • Each channel’s measurement statistics can be viewed at any time.
  • USB (virtual serial port) and LAN interface connections are available for easy connection to your company network or direct to you PC.
  • Category II safety rating to help protect you and your operators when making real-world measurements in industrial areas.
  • TQSoft and TQAero thermal validation software
  • Trend Link Software extends system capabilities
  • On-screen color trend graphing of up to four channels at a time
  • Easy-to-use menu system for setup and data management
  • Input types: ac V, dc V, ac I, dc I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency
  • 45 channels/second basic dc scan rate
  • Internal 57,000 scan/setup file memory

Specifications

  • Power:
    • Voltage: 100V to 264A in 4 power model selections (100V, 120V, 220V, 240V)
    • Frequency: 47Hz to 440Hz (automatically sensed when turned on)
    • Power Consumption: 34V A peak (24W average)
  • Universal Channels: 20
  • Channel Capacity:
    • Analog Inputs: 22 to 66 channels; 8  Digital I/O & 6 Alarm
    • Totalizer: 1
  • Temperature:
    • Operating: 0°C to 50°C
    • Storage: 20°C to 70°C
    • Warm-up: One hour to full uncertainty
  • Relative Humidity (non-condensing):
    • Operating: 0°C to 28°C <90%; 28°C to40 °C <75%; 40°C to 50°C <50%
    • Storage: 20°C to 70°C <95%
  • Communication:
    • LAN: 10/100 Mb TCPIP DHCP
    • Remote Commands: SCPI command set
  • DC Volts:
    • Range: 100MV to 300V
    • Resolution:  0.1µV to 1mV 
    • Accuracy: 0.0024%
  • AC Volts:
    • Range: 100 MV to 300 V
    • Resolution: 0.1µV to 1mV
    • Accuracy: 0.11%
  • Resistance:
    • Range: 100 Ω to 100 MΩ
    • Resolution:  0.1 mΩ to 100 Ω
    • Accuracy: 0.01%
  • Frequency:
    • Range: 20 Hz to 1 MHz
    • Accuracy: 0.01%
  • RTD (Pt 100):
    • Range: -200°C
    • Resolution: 0.001°C
    • Accuracy: 0.016°C
  • J Thermocouples:
    • Range: -200°C to 1,000°C
    • Resolution: 0.01°C
    • Accuracy: 0.53°C
  • K Thermocouples:
    • Range: -200°C to 1,000°C
    • Resolution: 0.01°C
    • Accuracy: 0.60°C
  • T Thermocouples:
    • Range: -270°C to 400°C
    • Resolution: 0.01°C
    • Accuracy: 0.62°C
  • Other Thermocouple Types: R, S, N, E, B, C, D, G, L, M, U & W
  • Internal Memory: 57,000 scans; 1000 setup files
  • File Security: Dual level, Administrator, five secure users, Guest status
  • Alarm Outputs: 6 TTL alarm outputs - assignable to one or multiple channels
  • Alarm Setpoints: 2 assignable setpoints/channel, Hi Lo, Hi Hi, Lo Lo
  • Language Menus: English, Chinese, French, German, Japanese, Korean, Portuguese, Russian & Spanish
  • Standard Rack Height: 3 U
  • Dimensions (L x W x H): 385mm x 285mm x 150mm
  • Weight: 6kg

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

6 Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.
Fluke Hydra 2638A Data Acquisition System; 20 Channel

Fluke Hydra 2638A Data Acquisition System; 20 Channel

$0.00
Fluke Hydra 2638A Data Acquisition System; 20 Channel

Fluke Hydra 2638A Data Acquisition System; 20 Channel

Recently viewed products