Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

FREE Shipping For Purchases Over $250 within Australia

Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

SKU: 802
$198.00
Checkout Secure
Need more info? Call us +61 8 9335 1718

Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

Product Overview 

The Calibration Kit allows you to perform dozens of recalibrations in the field, to ensure that your Kestrel is always performing within specifications.  In fact, if using distilled water, you can calibrate an indefinite number of times.  
The manual explains in detail all of the steps for recalibrating your Kestrel. This process will take approximately 13 hours (about 15 minutes of work), including setup and calibration.

 

Includes

  • Three clear, sealable containers
  • One container with magnesium chloride solution
  • One container with sodium chloride solution
  • Two wooden scrapers
  • An insulated carrying case to hold all of the above and maintain a stable environment while performing calibration
  • For use with: Kestrel 4500, Kestrel 4300, Kestrel 4200, Kestrel 4100, Kestrel 4000, Kestrel 3500, and Kestrel 3000 (Both the older 2 button and 4 button version)

 

How often do meters need to be re-calibrated?

Largely it’s dependent on whether it’s industrial use or consumer use. Acousticians recalibrate annually, firefighters annually or semi-annually, and general consumers might recalibrate them every 4 or 5 years or so. The official stance is that a calibration is recommended every 24 months due to the possibility of up to 2% calibration drift over 24 months.

If you're Kestrel Meter is flashing 'E1', this means the humidity sensor needs to be re-calibrated. If the unit is less 30 days old (from the date of purchase) you may send it back to Kestrel AU for re-calibration under warranty. If it has been more than 30 days from purchase, it can be returned to Kestrel AU for a humidity calibration for $65 plus shipping.  OR - you can buy this calibration kit and do it yourself.

 

Kestrel Calibration Kit Additional Information 

  • Kestrel Calibration Kit Instructions (PDF)
  • Weight 1.5 lbs / 680 grams
  • Place of Origin: USA

 

Kestrel Calibration Kit Video:

    Download Brochure

    Shipping This Item Ships from Fremantle, Perth, Western Australia
    Please allow 2 - 10 days for your order to arrive.

    Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

    Returns are easy.

    simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Description

    Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

    Product Overview 

    The Calibration Kit allows you to perform dozens of recalibrations in the field, to ensure that your Kestrel is always performing within specifications.  In fact, if using distilled water, you can calibrate an indefinite number of times.  
    The manual explains in detail all of the steps for recalibrating your Kestrel. This process will take approximately 13 hours (about 15 minutes of work), including setup and calibration.

     

    Includes

    • Three clear, sealable containers
    • One container with magnesium chloride solution
    • One container with sodium chloride solution
    • Two wooden scrapers
    • An insulated carrying case to hold all of the above and maintain a stable environment while performing calibration
    • For use with: Kestrel 4500, Kestrel 4300, Kestrel 4200, Kestrel 4100, Kestrel 4000, Kestrel 3500, and Kestrel 3000 (Both the older 2 button and 4 button version)

     

    How often do meters need to be re-calibrated?

    Largely it’s dependent on whether it’s industrial use or consumer use. Acousticians recalibrate annually, firefighters annually or semi-annually, and general consumers might recalibrate them every 4 or 5 years or so. The official stance is that a calibration is recommended every 24 months due to the possibility of up to 2% calibration drift over 24 months.

    If you're Kestrel Meter is flashing 'E1', this means the humidity sensor needs to be re-calibrated. If the unit is less 30 days old (from the date of purchase) you may send it back to Kestrel AU for re-calibration under warranty. If it has been more than 30 days from purchase, it can be returned to Kestrel AU for a humidity calibration for $65 plus shipping.  OR - you can buy this calibration kit and do it yourself.

     

    Kestrel Calibration Kit Additional Information 

    • Kestrel Calibration Kit Instructions (PDF)
    • Weight 1.5 lbs / 680 grams
    • Place of Origin: USA

     

    Kestrel Calibration Kit Video:

      Download Brochure

      Shipping

      Shipping This item ships to

      Delivery & Returns

      Please allow 2 - 10 days for your order to arrive.

      Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

      Returns are easy.

      simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

      Reviews

      6 Great reasons to buy from us:

      • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

        30 Days Return

        If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
      • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

        Returns are Easy

        Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
      • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

        Best Price Guarantee

        In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
      • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

        We guarantee your satisfaction

        We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
      • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

        100% Safe & Secure

        Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
      • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

        Best Laser Warranties in the Business

        Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.
      Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

      Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

      $198.00
      Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

      Kestrel RH Calibration Kit (3000, 3500, 4000 Series)

      $198.00

      Recently viewed products