Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

FREE Shipping For Purchases Over $250 within Australia

Fluke 1750/ET 3-phase Power Recorder, W/ Four 400a Current Probes (item no. 4871400)

SKU: 4871400

Not Available

Similar/Suggested Product:

Fluke 1773 Basic, Power Quality Analyzer (Item no. 5272757)

Fluke 1773 Basic, Power Quality Analyzer (Item no. 5272757)

SKU: 5272757

$12,059.00
Fluke 1775 Basic, Power Quality Analyzer (Item no. 5272784)

Fluke 1775 Basic, Power Quality Analyzer

SKU: 5272784

$15,970.00
Fluke 1777 Basic, Power Quality Analyzer (Item no. 5272819)

Fluke 1777 Basic, Three-Phase Power Quality Analyzers

SKU: 5272819

$19,881.00
Need more info? Call us +61 8 9335 1718

DISCONTINUED ITEM. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 4871400)

Record every power quality paramater, every cycle, all the time

Setting up a power quality analyzer to capture detailed power quality data has never been easier that it is with the Fluke 1750. The only things you need to know are the system voltage, frequency and the power configuration (delta or wye). The analyzer then captures the most important data for up to 30 days without losing the most important details. These power meters automatically record every power quality parameter and event, on every cycle – all the time. Once the data is captured download via Ethernet or directly to 2GB SD card (without the need of any other device). The Fluke 1750 features a wireless front panel for viewing measurements, data and setting up, implemented via a tablet computer using Bluetooth communication.

Common Applications

  • Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction
  • Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports
  • Quality of service compliance: Validate incoming power quality at the service entrance
  • Equipment Installation/Commissioning: Benchmark: power system prior to install to insure quality of service
    • Long-Term Analysis – Uncover hard-to-find or intermittent issues.
    • Load Studies – Verify the available electrical system capacity before adding loads.


Features

  • Three-phase power quality recorder with an Android tablet wireless front panel interface
  • Complies with IEC 61000-4-30 Class-A standards for correct evaluation of all measured values
  • Supports quick and reliable configuration even in awkward test locations with the wireless interface that provides a window into what the instrument is recording


    Specifications: Fluke 1750 Three-Phase Power Quality Logger

    Technical Specifications
    Power quality measurement standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A, S or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160
    Clock/calendar Leap years, 24-hour clock
    Real-time clock accuracy Not more than ±1 s/day
    Internal memory capacity for data At least 2 GB
    Maximum recording period At least 31 days
    Measurement time control Automatic
    Maximum number of events Limited only by the size of the internal memory
    Power requirements 100 to 240 V rms ±10%, 47-63 Hz, 40 W
    Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging
    Dimensions 215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)
    Mass (weight) 6.3 kg (14 lb)
    Input Measurement types One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye
    Input channels Voltage: 4 channels, AC/DC
    Current: 5 channels
    Voltage channels Input resistance: 2 MΩ
    Input capacitance: < 20 pF
    Current input characteristics 2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs
    Measuring method Simultaneous digital sampling of voltage and current. Digital PLL synchronised sampling, internal frequency reference used during voltage drops.
    Synchronisation and sampling synchronisation source The PLL synchronises to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterised as either wye or delta.
    PLL lock range 42.5 to 69 Hz
    Sampling frequency Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2 560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz
    A/D resolution Voltage and current: 24 bits
    Transient voltage: 14 bits
    Voltage and current measurements Voltage measurement range AC voltage: 1000 V rms ±10% over range
    DC voltage: ±1000 V + 10% over range
    Voltage crest factor 3 or less
    Current measurement range Depends on current probe used
    Current crest factor 4 or less
    RMS voltage Measurement type True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.
    Measurement uncertainty AC: ±0.2% reading ±0.1% full scale, above 50 V rms
    DC: ±0.5% reading ±0.2% full scale, above 50 V dc
    RMS current Measurement type True RMS calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Transient voltage (impulse) Measurement type Waveshape sampling
    Full scale 8000 V pk
    Sample resolution 200 nS
    Measurement uncertainty ±5% reading ±20 V (test parameters: 1000 V DC, 1000 V rms, 100 kHz)
    Voltage swell (rms swell) Measurement type True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data Amplitude and duration of swell
    Measurement Same as rms voltage
    Voltage dip (rms sag) Measurement type True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data Amplitude and duration of dip or interruption
    Measurement Same as rms voltage
    Voltage dropout (interruption) Measurement type Same as voltage dip
    LAN interface Connector RJ-45
    Speed and type 10/100 Base-T, auto MDIX
    Communications protocol TCP/IP over Ethernet
    Wireless controller interface Connection wireless (2.4 GHz radio)
    Speed up to 700 kbit/second
    Communications protocol Bluetooth SPP
    Power Measurements
    Power, battery life Measurement type True RMS calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Frequency Measurement range 42.5 to 69 Hz
    Measurement source Same as PLL synchronisation source
    Measurement accuracy ±10 mHz (10 to 110% of range, with sine wave)
    Power factor Measurement range 0.000 to 1.000
    Measurement accuracy ±1 digit from the calculation of each measured value (±3 digits for total)
    Displacement power factor Measurement method Calculated from the phase difference between voltage fundamental and current fundamental
    Measurement range - 1.000 (leading) to + 1.000 (lagging)
    Measurement accuracy ±0.5% reading ±2% full scale ±1 digit
    Voltage unbalance and phase sequence Measurement method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
    Harmonic voltage and current Analysis window rectangular
    Analysis order 1st to 50th order
    Measurement accuracy Voltage / Current: 1st to 20th orders: ±0.5% reading ±0.2% full scale, 21st to 50th orders: ±1% reading ±0.3% full scale (current sensor accuracy must be included for current and power)
    Measurement method IEC 61000-4-7
    Inter-harmonic voltage and current (intermediate harmonics) Analysis window rectangular
    Analysis orders 1.5 to 49.5th order
    Measurement method IEC 61000-4-7
    Flicker Measurement method IEC 61000-4-15
    Plt for 2 hours and Pst for 10 minutes
    Measuring range 0,1 to 5 (25) depending on voltage level, modulation and frequency
    Environmental Specifications
    Environmental Operating environment Indoors or in covered area outdoors, up to 2,000 m altitude
    Storage temperature and humidity -20°C to 50°C, 80% RH max, non-condensing
    Operating temperature and humidity 0°C to 40°C, 80% RH max, non-condensing
    Maximum rated working voltage Voltage terminals 1100 V rms
    Voltage durability 5550 V rms AC for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current)
    Enclosure protection IP30 (per EN 60529)
    Standards EMC EN 61326-1:1997+A1:1998 Class A
    EN 61000-3-2:1995+A1:1998+A2:1998
    EN 61000-3-3:1995
    Safety EN 61010-1 2 nd Edition; 2 000
    Voltage input unit: Contamination Level 2 , Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V)

     

    Includes:

    • 1750 acquisition unit
    • 1750 handheld tablet
    • 4 x 400A current probes (3140)
    • 5 Test leads and clips
    • 2GB SD Memory card (larger cards not compatible)
    • Fluke Power View and Fluke Power Analyze software
    • Power cord with international plug set
    • Ethernet cable
    • Color localization set
    • Printed Getting Started manual
    • Product CD with software and user manual PDF
    • CS 1750/1760 Rugged transit softcase

    Manuals

      Shipping This Item Ships from Fremantle, Perth, Western Australia
      Please allow 2 - 10 days for your order to arrive.

      Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

      Returns are easy.

      simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

      Description

      DISCONTINUED ITEM. Please contact Laserman for more information on +61 8 9335 1718 )

      (item no. 4871400)

      Record every power quality paramater, every cycle, all the time

      Setting up a power quality analyzer to capture detailed power quality data has never been easier that it is with the Fluke 1750. The only things you need to know are the system voltage, frequency and the power configuration (delta or wye). The analyzer then captures the most important data for up to 30 days without losing the most important details. These power meters automatically record every power quality parameter and event, on every cycle – all the time. Once the data is captured download via Ethernet or directly to 2GB SD card (without the need of any other device). The Fluke 1750 features a wireless front panel for viewing measurements, data and setting up, implemented via a tablet computer using Bluetooth communication.

      Common Applications

      • Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction
      • Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports
      • Quality of service compliance: Validate incoming power quality at the service entrance
      • Equipment Installation/Commissioning: Benchmark: power system prior to install to insure quality of service
        • Long-Term Analysis – Uncover hard-to-find or intermittent issues.
        • Load Studies – Verify the available electrical system capacity before adding loads.


      Features

      • Three-phase power quality recorder with an Android tablet wireless front panel interface
      • Complies with IEC 61000-4-30 Class-A standards for correct evaluation of all measured values
      • Supports quick and reliable configuration even in awkward test locations with the wireless interface that provides a window into what the instrument is recording


        Specifications: Fluke 1750 Three-Phase Power Quality Logger

        Technical Specifications
        Power quality measurement standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A, S or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160
        Clock/calendar Leap years, 24-hour clock
        Real-time clock accuracy Not more than ±1 s/day
        Internal memory capacity for data At least 2 GB
        Maximum recording period At least 31 days
        Measurement time control Automatic
        Maximum number of events Limited only by the size of the internal memory
        Power requirements 100 to 240 V rms ±10%, 47-63 Hz, 40 W
        Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging
        Dimensions 215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)
        Mass (weight) 6.3 kg (14 lb)
        Input Measurement types One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye
        Input channels Voltage: 4 channels, AC/DC
        Current: 5 channels
        Voltage channels Input resistance: 2 MΩ
        Input capacitance: < 20 pF
        Current input characteristics 2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs
        Measuring method Simultaneous digital sampling of voltage and current. Digital PLL synchronised sampling, internal frequency reference used during voltage drops.
        Synchronisation and sampling synchronisation source The PLL synchronises to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterised as either wye or delta.
        PLL lock range 42.5 to 69 Hz
        Sampling frequency Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2 560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz
        A/D resolution Voltage and current: 24 bits
        Transient voltage: 14 bits
        Voltage and current measurements Voltage measurement range AC voltage: 1000 V rms ±10% over range
        DC voltage: ±1000 V + 10% over range
        Voltage crest factor 3 or less
        Current measurement range Depends on current probe used
        Current crest factor 4 or less
        RMS voltage Measurement type True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.
        Measurement uncertainty AC: ±0.2% reading ±0.1% full scale, above 50 V rms
        DC: ±0.5% reading ±0.2% full scale, above 50 V dc
        RMS current Measurement type True RMS calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
        Transient voltage (impulse) Measurement type Waveshape sampling
        Full scale 8000 V pk
        Sample resolution 200 nS
        Measurement uncertainty ±5% reading ±20 V (test parameters: 1000 V DC, 1000 V rms, 100 kHz)
        Voltage swell (rms swell) Measurement type True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
        Displayed data Amplitude and duration of swell
        Measurement Same as rms voltage
        Voltage dip (rms sag) Measurement type True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
        Displayed data Amplitude and duration of dip or interruption
        Measurement Same as rms voltage
        Voltage dropout (interruption) Measurement type Same as voltage dip
        LAN interface Connector RJ-45
        Speed and type 10/100 Base-T, auto MDIX
        Communications protocol TCP/IP over Ethernet
        Wireless controller interface Connection wireless (2.4 GHz radio)
        Speed up to 700 kbit/second
        Communications protocol Bluetooth SPP
        Power Measurements
        Power, battery life Measurement type True RMS calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
        Frequency Measurement range 42.5 to 69 Hz
        Measurement source Same as PLL synchronisation source
        Measurement accuracy ±10 mHz (10 to 110% of range, with sine wave)
        Power factor Measurement range 0.000 to 1.000
        Measurement accuracy ±1 digit from the calculation of each measured value (±3 digits for total)
        Displacement power factor Measurement method Calculated from the phase difference between voltage fundamental and current fundamental
        Measurement range - 1.000 (leading) to + 1.000 (lagging)
        Measurement accuracy ±0.5% reading ±2% full scale ±1 digit
        Voltage unbalance and phase sequence Measurement method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
        Harmonic voltage and current Analysis window rectangular
        Analysis order 1st to 50th order
        Measurement accuracy Voltage / Current: 1st to 20th orders: ±0.5% reading ±0.2% full scale, 21st to 50th orders: ±1% reading ±0.3% full scale (current sensor accuracy must be included for current and power)
        Measurement method IEC 61000-4-7
        Inter-harmonic voltage and current (intermediate harmonics) Analysis window rectangular
        Analysis orders 1.5 to 49.5th order
        Measurement method IEC 61000-4-7
        Flicker Measurement method IEC 61000-4-15
        Plt for 2 hours and Pst for 10 minutes
        Measuring range 0,1 to 5 (25) depending on voltage level, modulation and frequency
        Environmental Specifications
        Environmental Operating environment Indoors or in covered area outdoors, up to 2,000 m altitude
        Storage temperature and humidity -20°C to 50°C, 80% RH max, non-condensing
        Operating temperature and humidity 0°C to 40°C, 80% RH max, non-condensing
        Maximum rated working voltage Voltage terminals 1100 V rms
        Voltage durability 5550 V rms AC for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current)
        Enclosure protection IP30 (per EN 60529)
        Standards EMC EN 61326-1:1997+A1:1998 Class A
        EN 61000-3-2:1995+A1:1998+A2:1998
        EN 61000-3-3:1995
        Safety EN 61010-1 2 nd Edition; 2 000
        Voltage input unit: Contamination Level 2 , Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V)

         

        Includes:

        • 1750 acquisition unit
        • 1750 handheld tablet
        • 4 x 400A current probes (3140)
        • 5 Test leads and clips
        • 2GB SD Memory card (larger cards not compatible)
        • Fluke Power View and Fluke Power Analyze software
        • Power cord with international plug set
        • Ethernet cable
        • Color localization set
        • Printed Getting Started manual
        • Product CD with software and user manual PDF
        • CS 1750/1760 Rugged transit softcase

        Manuals

          Shipping

          Shipping This item ships to

          Delivery & Returns

          Please allow 2 - 10 days for your order to arrive.

          Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

          Returns are easy.

          simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

          Reviews

          6 Great reasons to buy from us:

          • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

            30 Days Return

            If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
          • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

            Returns are Easy

            Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
          • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

            Best Price Guarantee

            In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
          • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

            We guarantee your satisfaction

            We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
          • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

            100% Safe & Secure

            Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
          • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

            Best Laser Warranties in the Business

            Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

          Recently viewed products