Two powerful tools in one
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switch gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
Features
- Insulation test voltages 500 V, 1000 V
- Insulation test: 0.1 MΩ to 600 MΩ
- Auto discharge of capacitive voltage
- AC/DC Voltage
- DC millivolts
- AC/DC milliamps
- Resistance (0.1 Ω to 50 MΩ)
- Continuity
- Three-year warranty
- Remote probe, test leads, alligator clips
- Rugged, utility hard case
- Auto power off to save battery power
- True RMS
- Large display with backlight
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- CAT III 1000V, CAT IV 600V measurement category
- Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work
Specifications: Fluke 1577 Insulation Multimeter
| Specifications |
| Voltage DC |
Maximum voltage |
1000 V |
| Accuracy |
±(0.2%+2) |
| Maximum resolution |
0.001 V |
| Voltage AC |
Maximum voltage |
1000 V |
| Accuracy |
±(2%+3) |
| Maximum resolution |
0.1 mV |
| Current DC |
Maximum amps |
400 mA |
| Amps accuracy |
±(1.0%+2) |
| Maximum resolution |
0.01 mA |
| Current AC |
Maximum amps |
400 mA |
| Amps accuracy |
±(2.0%+2)* |
| Maximum resolution |
0.01 mA |
| Resistance |
Maximum resistance |
50 MΩ |
| Accuracy |
±(1.2%+2) |
| maximum resolution |
0.1Ω |
| Insulation Test |
| Minimum test current @ 1kΩ/V |
1 mA |
| Test voltages |
500, 1000 V |
| Maximum resistance per test voltage |
50 V |
|
| 100 V |
|
| 250 V |
|
| 500 V |
|
| 1000 V |
600 MΩ |
| Maximum resolution per test voltage |
50 V |
0.01 MΩ |
| 100 V |
0.01 MΩ |
| 250 V |
0.1 MΩ |
| 500 V |
0.1 MΩ |
| 1000 V |
0.1 MΩ |
| Accuracy per test voltage |
50 V |
±(3% + 5) |
| 100 V |
±(3% + 5) |
| 250 V |
±(1.5% + 5) |
| 500 V |
±(2.0% + 5) |
| 1000 V |
±(2.0% + 5) |
| Environmental Specifications |
| Operating temperature |
–20°C to +55°C |
| Storage temperature |
-40°C to +60°C |
| Humidity (without condensation) |
0% - 95% (10°C – 30°C) 0% - 75% (30°C – 40°C) 0% - 40% (40°C – 55°C) |
| Operating altitude |
2000 m |
| Safety Specifications |
| Overvoltage category |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
| Agency approvals |
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
| Mechanical and General Specifications |
| Size |
203 x 100 x 50 mm (with holster) |
| Weight |
624 g |
| Warranty |
3 years |
| Battery life alkaline |
Meter use |
1000 hours |
| Insulation test use |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| IP rating |
IP40 |
Includes:
- Remote probe
- Test leads
- Alligator clips
- Hard case
- Four AA alkaline batteries
- Quick reference guide
- CD rom with manual
Manuals