(item no. 4353218, 4353229, 4353234)
Product overview
Fluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more
The 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.
Get the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once:
- Pressure measurement from internal or external sensor
- Sourced/simulated or measured mA values
- Temperature measured by optional RTD probe
Features
- Unique integrated electric pump for one handed pressure calibration
- Test pressure switches easily with easy-to-use switch test function
- Precision pressure adjust vernier for easy and accurate pressure calibration
- Ideal accuracy and performance (0.025%) for reference class transmitter calibration
- 30 psi, 150 psi and 300 psi pressure ranges
- Programmable pressure calibrator pump limit:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 750P Pressure Modules
- Pump cleanout ports reduce pump failures from moisture and fluid damage
- Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
- Precision temperature measurement with optional RTD probe
Model Specifications
Part Number |
Item Number |
FLUKE-719 30G | Electric Pressure Calibrator, 30 Psi, 2 Bar |
FLUKE-719 100G | Electric Pressure Calibrator, 100 Psi, 7 Bar |
FLUKE-719PRO-30G | Electric Pressure Calibrator, 30 Psig |
FLUKE-719PRO-150G | Electric Pressure Calibrator, 150 Psig |
FLUKE-719PRO-300G | Electric Pressure Calibrator, 300 Psig |
Specifications: Fluke 719Pro Electric Pressure Calibrator
Measurement | |||
Fluke-719Pro-30G | Range | -12 to 30 psi / -0.8 to 2 bar | |
Resolution | 0.001 psi / 0.0001 bar | ||
Fluke-719Pro-150G | Range | -12 to 150 psi / -0.8 to 10 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Fluke-719Pro-300G | Range | -12 to 300 psi / -0.8 to 20 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Accuracy | ±0.025% of full scale, 6 months ±0.035% of full scale, 1 year |
||
Temperature effect (all ranges) | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | ||
Dry air and non-corrosive gas only No effect on accuracy on all functions from 15°C to 35°C |
|||
Function | Range | Resolution | Accuracy (1 year) |
mA DC (simulation and measurement) | 0-24 mA DC | 0.001 mA | ±0.015% of reading ±2 counts |
1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate | |||
Volts DC (measurement only) | 30 V DC | 0.001 V | ±0.015% of reading ±2 counts |
No AC voltage measurement, do not exceed 30 V DC | |||
Temperature (measurement only, Pt100 RTD) | -50 to 150°C (-50°F to 302°F) |
0.01°C 0.01°F |
Temperature ±0.1°C (0.2°F) |
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory) | |||
Loop power supply | 24 V DC | N/A | 24 mA at 24 V |
Temperature effect (all functions) | - | - | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
No effect on accuracy on all functions from 15°C to 35°C | |||
Environmental | |||
Operating temperature | -10°C to +50°C | ||
Storage temperature (with batteries) | Per battery manufacturer's specification within storage specification below | ||
Storage temperature (without batteries) | -20°C to +60°C | ||
Power Requirements | |||
Battery | Eight (8) standard Alkaline AA batteries | ||
Battery life | 300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum | ||
Physical | |||
Dimensions (H x W x D) | 24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in) | ||
Weight | With holster 1.2 kg (2.5 lb) | ||
Connections | |||
Pressure | 1/8 inch female NPT | ||
Electrical | Standard banana jacks | ||
RTD | 4 pin miniature circular | ||
External module | 6 pin miniature circular | ||
Engineering Units (Configurable) | |||
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F |
Includes:
- Test leads with alligator clips
- Printed user's manual and user's manual on CD-ROM in 14 languages
- Fluid trap
- Carrying case
- 1/4 inch NPT to 1/4 inch ISO adapter
- Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
- Traceable Certificate of Calibration
Manuals
- 719 | Users manual
- 719 | Users manual supplement
- 718,719,724,725, 726 | Safety sheet
- 71X Series | Calibration manual
- 71X Series | Calibration manual supplement
- Premium Pressure Accessory Kit | Quick reference guide
Data Sheets
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
(item no. 4353218, 4353229, 4353234)
Product overview
Fluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more
The 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.
Get the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once:
- Pressure measurement from internal or external sensor
- Sourced/simulated or measured mA values
- Temperature measured by optional RTD probe
Features
- Unique integrated electric pump for one handed pressure calibration
- Test pressure switches easily with easy-to-use switch test function
- Precision pressure adjust vernier for easy and accurate pressure calibration
- Ideal accuracy and performance (0.025%) for reference class transmitter calibration
- 30 psi, 150 psi and 300 psi pressure ranges
- Programmable pressure calibrator pump limit:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
- Extended pressure measurement range with any of 29 750P Pressure Modules
- Pump cleanout ports reduce pump failures from moisture and fluid damage
- Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
- Precision temperature measurement with optional RTD probe
Model Specifications
Part Number |
Item Number |
FLUKE-719 30G | Electric Pressure Calibrator, 30 Psi, 2 Bar |
FLUKE-719 100G | Electric Pressure Calibrator, 100 Psi, 7 Bar |
FLUKE-719PRO-30G | Electric Pressure Calibrator, 30 Psig |
FLUKE-719PRO-150G | Electric Pressure Calibrator, 150 Psig |
FLUKE-719PRO-300G | Electric Pressure Calibrator, 300 Psig |
Specifications: Fluke 719Pro Electric Pressure Calibrator
Measurement | |||
Fluke-719Pro-30G | Range | -12 to 30 psi / -0.8 to 2 bar | |
Resolution | 0.001 psi / 0.0001 bar | ||
Fluke-719Pro-150G | Range | -12 to 150 psi / -0.8 to 10 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Fluke-719Pro-300G | Range | -12 to 300 psi / -0.8 to 20 bar | |
Resolution | 0.01 psi / 0.001 bar | ||
Accuracy | ±0.025% of full scale, 6 months ±0.035% of full scale, 1 year |
||
Temperature effect (all ranges) | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C | ||
Dry air and non-corrosive gas only No effect on accuracy on all functions from 15°C to 35°C |
|||
Function | Range | Resolution | Accuracy (1 year) |
mA DC (simulation and measurement) | 0-24 mA DC | 0.001 mA | ±0.015% of reading ±2 counts |
1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate | |||
Volts DC (measurement only) | 30 V DC | 0.001 V | ±0.015% of reading ±2 counts |
No AC voltage measurement, do not exceed 30 V DC | |||
Temperature (measurement only, Pt100 RTD) | -50 to 150°C (-50°F to 302°F) |
0.01°C 0.01°F |
Temperature ±0.1°C (0.2°F) |
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory) | |||
Loop power supply | 24 V DC | N/A | 24 mA at 24 V |
Temperature effect (all functions) | - | - | Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |
No effect on accuracy on all functions from 15°C to 35°C | |||
Environmental | |||
Operating temperature | -10°C to +50°C | ||
Storage temperature (with batteries) | Per battery manufacturer's specification within storage specification below | ||
Storage temperature (without batteries) | -20°C to +60°C | ||
Power Requirements | |||
Battery | Eight (8) standard Alkaline AA batteries | ||
Battery life | 300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum | ||
Physical | |||
Dimensions (H x W x D) | 24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in) | ||
Weight | With holster 1.2 kg (2.5 lb) | ||
Connections | |||
Pressure | 1/8 inch female NPT | ||
Electrical | Standard banana jacks | ||
RTD | 4 pin miniature circular | ||
External module | 6 pin miniature circular | ||
Engineering Units (Configurable) | |||
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F |
Includes:
- Test leads with alligator clips
- Printed user's manual and user's manual on CD-ROM in 14 languages
- Fluid trap
- Carrying case
- 1/4 inch NPT to 1/4 inch ISO adapter
- Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
- Traceable Certificate of Calibration
Manuals
- 719 | Users manual
- 719 | Users manual supplement
- 718,719,724,725, 726 | Safety sheet
- 71X Series | Calibration manual
- 71X Series | Calibration manual supplement
- Premium Pressure Accessory Kit | Quick reference guide
Data Sheets
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.