(item no. 3729961)
The ACDC-52NAV clamp-on power meter is the ideal choice for jobs that require AC/DC current measurements to 600A, AC/DC voltage to 1000V and wide jaws to accommodate large conductors.
This AC/DC current clamp meter offers a full range of power quality diagnostics including power and power factor, total harmonics distortion, individual harmonics, in-rush current, phase sequence, TRMS and low pass filter for industrial power monitoring and verifying system conditions.
Features
- True-rms technology improves accuracy in noisy environments
- Measures AC/DC voltage to 1000V, AC/DC current to 600A, plus resistance, frequency, capacitance, power and power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency on variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph presents the full picture
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open to illuminate dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates large conductors up to 1.45 (37mm)
- Rubber overmold body absorbs shocks—drop proof to 4 feet (1.2m)
- CAT IV-rated AC/DC current clamp meter
- Includes test leads, batteries (installed), deluxe carrying case, and user's manual
Specifications
| AC Current |
100.00 A, 600.0 A |
100.00 A, 1000.0 A |
+/- (1.5 % rdg + 5 LSD) |
| DC Current |
_ |
_ |
100.00 A, 600.0 A |
_ |
100.00 A, 1000.0 A |
+/- (1.5 % rdg + 5 LSD) |
| AC Voltage |
100.00 V, 1000 V |
+/- (1.0 % rdg + 5 LSD) |
| DC Voltage |
100.00 V, 1000 V |
+/- (0.7 % rdg + 2 LSD) |
| Resistance |
1.0000 KO, 10.00 KO, 100.00 KO |
+/- (1.0 % rdg + 3 LSD) |
| Frequency |
20.0 Hz to 10 KHz |
+/- (0.5 % rdg +3 LSD) |
| Capacitance |
400.0 µF, 4.000 mF |
+/- (1.9 % rdg + 8 LSD) |
| DCµA |
_ |
1000.0 µA |
_ |
_ |
_ |
+/- (1.7 % rdg + 2 LSD) |
| Temperature |
_ |
-50 °F → 1832 °F (-50 ºC → 1000 ºC) |
_ |
_ |
-50 °F → 1832 °F (-50 ºC → 1000 ºC) |
+/- (1 % rdg + 0.8 ºC) |
| THD (total harmonics distortion) |
0.1% → 100.0% |
+/- (3.0 % rdg + 10 LSD) |
| Individual harmonics |
1 → 25 |
_ |
| Power |
10 kW → 600 kW |
10 kW → 1000 kW |
+/- (2.5 % rdg + 5 LSD) |
| Power factor |
-1.00 → 1.00 |
+/- 3 degrees |
| Accommodates conductors |
Up to 1.45“ (37 mm) in diameter |
Up to 1.60“ (40 mm) in diameter |
Download
Product Manual »
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!